ENGINEERING TOOLBOX · INTERACTIVE CALCULATOR
Connector Contact Resistance, Voltage Drop & Temperature Rise Calculator
Input your continuous current (A), bus voltage (V), contact resistance per pin (mΩ), and parallel contact count to calculate total circuit voltage drop, Joule heat dissipation, and optional temperature rise (ΔT) using measured effective thermal resistance. Select one pole or both supply and return contacts.
Voltage drop and losses are calculated. Temperature estimates require measured effective thermal resistance for the same assembly, mounting and cooling conditions.
R_eff = S × R_contact / N; ΔV = I × R_eff; P = I² × R_eff; ΔT = P × θ_eff.
S is the number of series contact groups; N is equal-resistance parallel contacts per pole. Equations use Ω. Wire, PCB and solder resistance, unequal current sharing and temperature-dependent resistance are excluded. Thermal resistance depends on geometry, mounting and cooling; there is no universal default.
IEC 60512-5-2 defines a current-temperature derating test method; this tool does not perform that test.