ENGINEERING TOOLBOX · INTERACTIVE CALCULATOR

Connector Contact Resistance, Voltage Drop & Temperature Rise Calculator

Input your continuous current (A), bus voltage (V), contact resistance per pin (mΩ), and parallel contact count to calculate total circuit voltage drop, Joule heat dissipation, and optional temperature rise (ΔT) using measured effective thermal resistance. Select one pole or both supply and return contacts.

Example inputs, not product ratings:
A
V
mΩ
N
°C
K/W
Circuit estimate — not a compliance verdict

Voltage drop and losses are calculated. Temperature estimates require measured effective thermal resistance for the same assembly, mounting and cooling conditions.

Resistance in selected scope2.50mΩ
Contact voltage drop75.0mV (0.16%)
Contact power loss2.25W
Estimated temperature rise—K · Hot spot: — °C
Model and scope

R_eff = S × R_contact / N; ΔV = I × R_eff; P = I² × R_eff; ΔT = P × θ_eff.

S is the number of series contact groups; N is equal-resistance parallel contacts per pole. Equations use Ω. Wire, PCB and solder resistance, unequal current sharing and temperature-dependent resistance are excluded. Thermal resistance depends on geometry, mounting and cooling; there is no universal default.

IEC 60512-5-2 defines a current-temperature derating test method; this tool does not perform that test.